The government updated building forms from 1 September 2021 as part of the new Building Regulation 2021.
The following forms should now be used by competent persons when providing design or inspection certification.
New Form | Old Form | Purpose | Examples |
---|---|---|---|
Form 12 – Aspect inspection certificate (Appointed competent person) |
Form 16 – Aspect Certificate/QBCC Licensee Aspect Certificate |
Competent person must give this form to the certifier when inspected work complies. | • Boundary clearances (Surveyor) • Excavation of foundation material (Engineer) • Compaction of fill material (Engineer) • Smoke Alarms (Electrician) |
Form 15 – Compliance certificate for a building design or specification |
Update to form design only | Competent person must give this form to the certifier for design work. | • Energy efficiency (Assessor) • Structural design (Engineer) • Roof truss |
Form 43 – Aspect certificate (QBCC licensee) |
Form 16 – Aspect Certificate/QBCC Licensee Aspect Certificate |
QBCC licensee gives this form to the certifier when work complies. | • Cut & fill batters (Licensed builder) • Termite management system (Licensed installer) • Energy efficiency (Licensed builder) • Waterproofing (Licensed installer) |
Form 62 – Notice that the stage of work does not comply (Appointed competent person) |
Form 61 Non-compliance notice |
Competent person is not satisfied the stage or work complies. |
New Form | Old Form | Purpose | Examples |
---|---|---|---|
Form 12 – Aspect inspection certificate (Appointed competent person) |
Form 16 – Aspect Certificate/QBCC Licensee Aspect Certificate |
Competent person must give this form to the certifier when inspected work complies. | • Structural construction (Engineer) • Waterproofing (Licensed installer) • Termite management system (Licensed installer) |
Form 15 – Compliance certificate for a building design or specification | Update to form design only | Competent person must give this form to the certifier for design work. | • Energy efficiency (Assessor) • Structural design (Engineer) |
Form 62 Notice that the stage of work does not comply (Appointed competent person) |
Form 61 Non-compliance notice |
Competent person is not satisfied the stage or work complies. |
NCC 2022, effective from May 2023, revised shower floor grading to be minimum 1:80 to maximum 1:50. This applies to all States and is irrespective…
HIA has issued advice regarding the changes to branch drain connections in the revised NCC 2022. For further information, see the link below:…
Brisbane City Council has now published further information about changes to siting variations which can be found at: https://www.brisbane.qld.gov.au/planning-and-building/do-i-need-approval/types-of-approval/building-near-the-boundary